Recommended torque for B7 studs (ASTM A193) based on 50% yield

Note: These are just guidelines. Consult the manufacturer’s specifications or your engineering department for your company’s specifications.

Bolt diameter Heavy Hex Nut Size (AF) Lubricated Using Copper, Graphite, or Other Comparable Lubricant *; Friction Coefficient = 0.100 (Values ​​in lb-ft) Steel on Steel, Dry, Lubricant-Free, Coefficient of Friction = 0.400 (Values ​​in lb-ft)
3/4″ 1-1/4″ 157 559
7/8″ 1-7/16″ 250 893
1″ 1-5/8″ 373 1.332
1-1/8″ 1-13/16″ 538 1.994
1-1/4″ 2″ 746 2.720
1-3/8″ 2-3/16″ 1.000 3.678
1-1/2″ 2-3/8″ 1.307 4.837
1-5/8″ 2-9/16″ 1.682 6.260
1-3/4″ 2-3/4″ 2.109 7.888
1-7/8″ 2-15/16″ 2.602 9.775
2″ 3-1/8″ 3.167 11.942
2-1/8″ 3-5/16″ 3.809 14.408
2-1/4″ 3-1/2″ 4.531 17.191
2-3/8″ 3-11/16″ 5.339 20.310
2-1/2″ 3-7/8″ 6.238 23.786
2-3/4″ 4-1/4″ 7.533 28.846
3″ 4-5/8″ 9.803 37.670
3-1/4″ 5″ 12.488 48.129
3-1/2″ 5-3/8″ 15.622 60.365
3-3/4″ 5-3/4″ 19.241 74.516
4″ 6-1/8″ 22.162 86.146
4-1/4″ 6-1/2″ 23.337 90.720
4-1/2″ 6-7/8″ 26.332 102.513
4-3/4″ 7-1/4″ 30.994 120.831
5″ 7-5/8″ 36.176 141.210

* Nut and thread must be lubricated.